Analog Inputs:
Yes
Analog Output:
Yes
Analogue Ouput Signal:
4 - 20 mA
Calculations:
Discharge using Parshall Flume, Broad Crested Weir equations, Dual Sensor, Rating Table or general purpose equation with user entered constants.
Calculation of daily volume and daily average stage.
Control and Display:
Display Type: 2 x 20 LCD with backlight
Keypad Type: 6 button
Data Storage:
˃ 300,000 readings
Dimensions:
4.5 x 4 x 7 in (11.5 x 10.2 x 17.8 cm)
Interface:
SDI-12, RS-232
Material Enclosures:
NEMA 3, IP63 resists dripping water & spray
Measuring Interval:
15-minute (default)
1, 5, and 10-min user selectable
Measuring Range:
+/- 24.38 m of calibration point
Operating Temperature Range:
-40 - +140 °F (-40 - +60 °C)
Parameters Measured:
Stage / Water Level, Internal Temperature, Battery
Power Consumption:
˂3.5 mA @12 VDC
Power Supply:
5.5 - 16 VDC
Programming:
Via front panel or SDR communicator program
Protocol:
MODBUS Slave. SCP, SDI-12
Range:
+/- 80 ft (24.38 m) of calibration point
Resolution:
Analog input measures 0 - 5 V sensor, 4 - 20 mA sensor or resistive bridge sensor
SD Card:
Yes
Shaft Encoder:
No