OTT Hydromet - Add-on for Orckestra
1-800-423-3015

OTT PLS-C Pressure Level Sensor with Conductivity, 0 - 20 m, SDI-12

OTT PLS-C Pressure Level Sensor with Conductivity, 0 - 20 m, SDI-12
Product #: 63.038.001.9052
Unit Price Get Quote

Ceramic pressure cell

The robust ceramic pressure cell offers industry-leading accuracy and does not deform over time like membrane technology, providing long-term measurement stability

Rugged design

Ceramic pressure cell resistant to physical force (4 x burst pressure) and enclosure made of high-quality saltwater resistant steel for use in coastal environments.

Vented pressure probe

Vented pressure probe, automatically compensates for changes in barometric pressure.

Auto compensation

Built-in microcontroller – compensates for temperature effects and applies correction values for gravitational acceleration or water density.

Simple setup

Simple setup and connection to external dataloggers using SDI-12.

Specifications

*Parameters Measured: Water level
Pressure
Temperature
Conductivity
Accuracy: Water Level: ±0.05 % FS (linearity and hysteresis)
Temperature: ±0.2 °F (±0.1 °C)
Conductivity 5 - 2000 µS/cm: ±1 µS/cm or ± 0.5 % of measured value (whichever is higher)
Conductivity 0.1 - 100 mS/cm: ± 0.01 mS/cm or ±1.5 % of measured value (whichever is higher)
Body material: Stainless steel 1.4539 (904L) resistant to sea water
Calibrated Range: +41 - +113 °F (+5 - +45 °C)
Interface: SDI-12
Measuring Range: 0 - 66 ft (0 - 20 m)
Power Consumption: Sleep: ≤ 30 µA
Active: ≤ 32 mA
Power Supply: 6 - 27 V DC, typically 12/24 V DC
Protection Class: IP 68
Resolution: 0.01 ft; 0.001 psi (0.001 m; 0.1 cm; 0.1 mbar)
Standard storage temperature: -40 - +185 °F (-40 - +85 °C)
Temperature Compensation: +23 - +113 °F (-5 - +45 °C) (ice-free)
Temperature Range: -13 - +158 °F (-25 - 70 °C) (ice-free)