*Parameters Measured:
Air Temperature
Relative Humidity
Precipitation Intensity
Precipitation Type
Precipitation Quantity
Air Pressure
Wind Direction
Wind Speed
Solar Radiation
Air Pressure:
Accuracy: ±0.5 hPa (0 - +104 °F) or ±0.5 hPa (0 - +40 °C)
Measuring range: 300 - 1200 hPa
Measurement technology: MEMS capacitive
Air Temperature:
Accuracy: ±0.4 °F (-4 - +122 °F) or ±0.2 °C (-20 - +50 °C), otherwise ±0.9 °F (˃ -22 °F) or ±0.5 °C (˃ -30 °C)
Measuring range: -58 - +140 °F (-50 - +60 °C)
Measurement technology: NTC
Resolution: 0.1 °C (-20 - +50 °C), otherwise 0.2 °C
Analog Inputs:
1
Cable Connection:
Open wires
Cable Length:
33 ft (10 m)
Communication:
SDI-12 and RS485 with supported protocols
UMB-Binary, UMB-ASCII, Modbus-RTU, Modbus-ASCII, XDR
Dimensions:
Ø150 x 344 mm
Interface:
RS485 2 wire
Baud rate: 1200 - 38400 bit/s (Standard: 19200) or SDI-12
IP Rating:
IP66
Material Enclosures:
Plastics (PC)
Operating Humidity:
0 - 100 %
Operating Temperature Range:
-50 - +60 °C
Power Consumption:
40 VA
Power Supply:
12 - 24 VDC
Precipitation:
Accuracy: 20 %
Measuring range: 0 - 200 mm/h
Measurement technology: 24 GHz Radar
Relative Humidity:
Accuracy: ±2 % RH
Measuring range: 0 - 100 % RH
Measurement technology: Capacitive
Solar Radiation:
Accuracy: 5 %
Measuring range: Maximum operational irradiance; 1400 W/m²
Measurement technology: Si-photodiode, optoelectric
Non-linearity: N.A.
Non-stability: N.A.
Water Level:
Accuracy: ±0.3 m/s or ±3 % (0 - 35 m/s) ±5 % (˃35 m/s) RMS
Measuring range: 0 - 75 m/s
Measurement technology: Ultrasonic
Weight:
3.3 lb (˂ 1.5 kg)
Wind Direction:
Accuracy: ˂ 3° RMSE ˃ 1.0 m/s
Measuring range: 0 - 359.9 °
Measurement technology: Ultrasonic
Wind Speed:
Accuracy - ±0,3 m/s or ±3 % (0 - 35 m/s) ±5 % (˃35 m/s) RMS
Measurement Range - 0 - 75 m/s
Measurement Technology - Ultrasonic