Analog Outputs:
N.A.
Cable Length:
66 ft (20 m)
Classification:
Fast response Class C (ISO 9060:2018)
Digital Outputs:
Modbus RTU 2-wire RS-485
Directional Response:
˂ 1.7 % (up to 55 ° with 1000 W/m² beam)
Drying Cartridge and Maintenance Interval:
Internal, no replacement necessary
IP Rating:
IP67
Irradiance Saturation:
2000 W/m² (Max.)
Material Enclosures:
Aluminum, anodised
Non-linearity:
˂ 1% (0 - 100 W/m²)
Non-stability:
˂ 1% (change/year)
Operating Humidity:
0 - 100 %
Operating Temperature Range:
-40 - +176 °F (-40 - +80 °C)
PV Panel Temperature:
-20 - +100 °C, ±1 °C
Response Time:
1 s (95 %)
Sensitivity:
N.A.
Spectral Accuracy:
400 - 1100 nm
Temperature Correction:
˂ 3.5 %: -4 - +176 °F (-40 - +80 °C)
Weight:
1.1 lb (500 g)
Zero offset A:
None
Zero offset B:
None